High Voltage model VLF-6022CM AC Hipot Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up to make sure that your testing is going smoothly!

High Voltage model VLF-6022CM AC Hipot Tester
  • Features & specifications

  • Input (CM suffix): 120V, 60Hz, 15 amps peak, 7.5 amps average
  • Input (F suffix): 230V, 50/60Hz, 8 amps peak, 4 amps average
  • Output: 0 to 60kVac peak, frequency selectable at 0.1/0.05/0.02 Hz
  • Comprises a control unit (75 lb) and a high voltage tank (120 lb)
  • Voltmeter: 0-60 kVac peak
  • Charging Current meter: 0 to 100mA peak
  • Load Capacitance meter: 0 to 6 Microfarads peak
  • Shielded RG/BU output cable: 20 ft. (6 m), Interconnect cable: 10 ft. (3 m)
  • Shipping weight: 330 lbs.

Specifications
Input 120 volts, 60 Hz, 15 A peak, 7.5 A average
or 230 volts, 50/60 Hz, 8 A peak
Output 0-62 kVac peak, 0.1 Hz - 0.02 Hz
Duty Continuous
Load rating 1.1 μF @ 0.1 Hz, 2.2μF @ 0.05 Hz, & 5.5 μF @ 0.02 Hz
Metering Voltmeter: 0 - 65 kVac peak
Charging Current meter: 0 - 100 mA peak
Load capacitance meter: 0 - 6 μF
Settable test duration timer
Cable lengths Shielded EPR output cable - 20 ft. (6 m)
Interconnect cable - 10 ft. (3 m)
Size & Weight Controls: 26"W x 13"D x 16"H, 75 lbs.
660 mm W x 330 mm D x 406 mm H, 34 kg
HV Tank: 15"W x 10.25"D x 21.5"H, 120 lbs.
381 mm W x 260 mm D x 546 mm H, 54 kg