High Voltage model VLF-50CMF AC Hipot Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up to make sure that your testing is going as planned!

High Voltage model VLF-50CMF AC Hipot Tester
  • Features & specifications

  • Input: 230V, 50/60Hz, 30 amps peak, 25 amps average
  • Output: 0 to 50kVac peak, at 0.1/0.05/0.02/0.01 Hz sinusoidal
  • Rated load (approx.): 5 μF at 0.1 Hz, 10 μF at 0.05 Hz, 25 μF at 0.02 Hz, 50 μF at 0.01 Hz
  • Duty continuous
  • Comprises a Control unit (20 lb), a Regulator (160 lb), and an HV tank (215 lb)
  • Voltmeter: 0 to 50 kVac peak
  • Charging Current meter: 0 to 200mA peak
  • Load Capacitance meter: 0 to 6 Microfarads peak
  • A user programmable test duration meter is included
  • Shielded EPR output cable: 100 ft. (30 m), Ground cable: 100 ft. (30 m)
  • Shipping weight: Approximately 500 lbs.

Specifications
Input 230 V ±10%, 50/60 Hz, single phase, 30 A peak, 25 A average
Output Sinusoidal 0 to 50 kVac peak, 0.1, .05, .02 and .01 Hz frequency
Duty Continuous
Test Capacitance 5.0 mF @ .1 Hz, 10.0 mF @ .05 Hz, 25.0 mF @ .02 Hz, 50.0 mF @ .01 Hz
Kilovoltmeter 3.5 in., 0 - 60 kVac peak 2% FS Accuracy
Current Load 3.5 in., 0 - 200 mAac peak 5% FS Accuracy
Capacitance Meter 0 - 6 mF with x1 & x10 ranges
Sizes Controls: 17"W x 11"D x 9.5"H, 20 lbs., 432 mm W x 280 mm D x 241 mm H, 9 kg
Power Section: 20"W x 14"D x 27"H, 160 lbs., 508 mm W x 356 mm D x 686 mm H, 73 kg
HV Tank size: 13.5"W x 19"D x 23"H, 310 lbs., 343 mm W x 483 mm D x 584 mm H, 141 kg
Complete Trolley: 28"W x 60"D x 51"H, 775lbs., 711 mm W x 1524 mm D x 1295 mm H, 352 kg
Output Cable Length Shielded X-Ray/Ground on reels - 100 ft. (30 m)