No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.
| Insulation Resistance | Values up to 106 MΩ at test voltages of 2.5 kV or 5 kV DC (a scale factor for other test voltages is provided) |
|---|---|
| Leakage current | 0.01 to 5,000 μA DC 0.1 to 5 mA AC |
| Input | 120 VAC, 60 Hz, single phase, 0.3 A or 230 VAC, 50/60 Hz, single phase 0.15 A |
| Output | ≈ 0 to 5 kV AC, 0 to 5 mA ≈ 0 to 6 kV DC, 0 to 5 mA Negative output, positive ground |
| Metering | 3½" analog meter Accuracy: ±2% of full scale |
| Voltmeter | 2 ranges: 0 to 3 kV and 0 to 6 kV |
| Current Meter | 0 to 5 mA AC 0 to 0.5/5/50/500/5000 μA DC |
| Resistance (MΩ) | 2,500 V: 0.5 to 50, 5 to 500, 50 to 5000, 500 to 50,000, 5,000 to 500,000 5,000 V: 1 to 100, 10 to 1,000, 100 to 10,000, 1,000 to 100,000, 10,000 to 1,000,000 |
| Dimensions | 18"L X 11"W X 11.5"H (457 X 279 X 292)mm |
| Weight | Net weight: 23 lbs (10 kg) |
| Cables and documentation |
|