High Voltage Inc ALT-120/60F Aerial Lift Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up to make sure that your testing is going as planned!

High Voltage Inc ALT-120/60F Aerial Lift Tester
  • Features & specifications

  • Input: 120 V, 60 Hz, 30 amps
  • Input (F suffix): 230 V, 50/60Hz, 15 amps
  • Output: 0 - 120 kVac, at 7 kVA, 60 mA, or 0 - 60 kVac at 7 kVA, 117 mA
  • Duty at 7 kVA: 1 hour ON, 2 hours OFF, or 4 kVA continuous
  • Distortion is less than 5%
  • Case: 21"w x 11.25"d x 15.25"h, 46 lbs.
  • Tank: 15.5"w x 15.5"d x 27.5"h, 160 lbs.
  • Output termination: Top toroid for 120 kV, side tap for 60 kV. No output cable provided or available.

Specifications
Input 120 V, 60 Hz, 30 A
(F) 230 V, 50/60 Hz, 15 A
Output 0-120 kV AC/0-60 kV AC
7 kVA capacitive (1.3 μF at 120 kV, 5.3 μF at 60 kV)
Duty 7 kVA: 1 hour ON, 1 hour OFF
4 kVA: Continuous
Voltmeter 3.5", scaled 0-30/60 kV and 0-60/120 kV AC RMS ± 2% F.S.
Current Meter 3.5", scaled 0-250 μA and 0-1.0 mA ± 2% F.S. with multipliers: x1, x10, x100 up to 100 mA
Distortion Less than 5%
Size and Weight
(W x D x H)
Case: 21 x 11.25 x 15.25 in., 46 lb.,
HV Tank: 15.5 x 15.5 x 27.5 in., 160 lb.