Prova 2000 AC/DC Clamp Meter

Request a Quotation
Back to Clamp Meters

AC/DC Clamp Meter
MODEL: Prova-2000
Prova 2000 Clamp Meter - Price: $450.00
  • DC 2500A, AC 2100A
  • 55mm dia., Bus Bar 65mm x 24mm
  • True RMS, Autorange, Diode test
  • Integrated Current Probe with analog output for Chart Recorder or Oscilloscope
  • 3¾ digit display with fast bar graph
  • 4000 counts of resolution
  • Max/Min/Hold & Continuity
  • Relative Measurement
  • Warranty: Two years
  • Price: $450.00 US dollars

SPECIFICATIONS: (23°C ± 5°C)
DC Current
Range Resolution Accuracy (of rdg) Overload Protection
400A 0.1A ± 1.5% ± 3dgts 3000 amps DC
0-2000A 1A ± 1.5% ± 3dgts 3000 amps DC
2000-2500A 1A ± 2.0% ± 3dgts 3000 amps DC

AC Current: (True RMS, Crest factor < 4)
    Accuracy (of rdg) Overload Protection
Range Resolution 50/60 Hz 40Hz - 1kHz
400A 0.1A ± 1.5% ± 5dgts ± 2.0% ± 5dgts 3000 amps AC
0-1000A 1A ± 2.0% ± 5dgts ± 2.5% ± 5dgts 3000 amps AC
1000-2100A 1A ± 2.5% ± 5dgts ± 3.0% ± 5dgts 3000 amps AC

Analog Output Current:
Range Output Accuracy Overload Protection
0-400A 1mV/A ± 2.5% ± 0.5A 600 volts AC
400A-2100A 1mV/A ± 2.5% ± 5A 600 volts AC

DC Voltage: (Autorange & Manual. Overload protection 800VAC for all ranges)
Range Resolution Accuracy (of rdg) Input Impedance
40mV 0.1 mV ± 1.5% ± 3dgts 10MΩ
4V 1 mV ± 1.5% ± 3dgts 5MΩ
40V 10 mV ± 1.5% ± 3dgts 5MΩ
400V 100 mV ± 1.5% ± 3dgts 5MΩ
600V 1V ± 1.5% ± 3dgts 5MΩ

AC Voltage: (True RMS, Crest Factor < 4. Input impedance 5 MΩ)
    Accuracy Overload Protection
Range Resolution 50/60 Hz 40Hz - 1kHz
400mV 0.1mV --------1 --------1 --------1
4V 1 mV ± 1.5% ± 5dgts ± 2.0% ± 5dgts 800 volts AC
40V 10 mV ± 1.5% ± 5dgts ± 2.0% ± 5dgts 800 volts AC
400V 100 mV ± 1.5% ± 5dgts ± 2.0% ± 5dgts 800 volts AC
600V 1V ± 1.5% ± 5dgts ± 2.0% ± 5dgts 800 volts AC
1Although 400mV AC can be selected by the RANGE key, the Prova 2000 is not designed to measure AC millivolts. Consequently no accuracy is listed for the 400mV AC range. For accurate millivolt measurements, see: Multimeters

Resistance: (Autorange & Manual. Open Circuit Voltage ≤ 0.5V)
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω ± 1.5% ± 3dgts 600 volts AC
4kΩ ± 1.5% ± 3dgts 600 volts AC
40kΩ 10Ω ± 1.5% ± 3dgts 600 volts AC
400kΩ 100Ω ± 1.5% ± 3dgts 600 volts AC
4MΩ 1kΩ ± 1.5% ± 3dgts 600 volts AC
40MΩ 10kΩ ± 1.5% ± 3dgts 600 volts AC

Continuity: (Overload protection 600VAC. Open circuit voltage 0.4V)
Range Resolution Accuracy Beeping
40Ω-400Ω 0.1Ω ± 1.0% ± 2dgts < 40.0Ω

Diode Test:
Range Resolution Accuracy Overload Protection
3V 0.001V ± 2.5% ± 5dgts 600 volts AC

Frequency: (OL protection 600VAC. Sensitivity selected with RANGE button)
Range Resolution Accuracy Sensitivity
100Hz-1000kHz 0.01Hz - 100Hz ± 0.5% ± 2dgts 10mV/100mV/1V

General specifications:
Applicable standards EN 61010-2-032, CAT III 600V, Pollution Degree 2
Conductor size Cable diameter 55mm approximately (2.2")
Bus Bar 65mm(D) x 24mm(W), (2.6" x 0.9")
Display 3¾ digit LCD with 40 segment bar graph
Operating temperature 4°C to 50°C
Dimensions 271(L) x 112(W) x 46(H)mm, (10.7" x 4.4" x 1.8")
Weight 647g (batteries included), (1½ lb approx.)
Accessories included User's Manual, 9V battery, Carrying Bag

This instrument is usually shipped within 48 hours. You can buy it now at a secure site by clicking on the button below, or by calling (800) 268-4928.

Prova 2000 Clamp Meter - Price: $450.00

Request a Quotation
Back to Clamp Meters


Instrumentation Sales & Rentals
"The Ultimate Source of Quality Test Equipment"


PO Box 10188, 27 Legend Court
Ancaster, ON L9K 1P3 Canada
600 Main Street, PO Box 888
Tonawanda, NY 14151 USA
Phone: (800) 268-4928 or (905) 667-3991