Agilent Technologies

Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.

Agilent E5515C Cellular Mobile Station (handset) Manufacturing Test Set
The E5515C is a multiple format manufacturing test set designed for high volume production testing of cellular and PCS telephone handsets. Depending on installed (E19XXX) test application, the E5515C can test AMPS, GSM, TDMA, CDMA2000, and GPRS handsets.

Agilent 16500B Mainframe
Modular logic analysis system that provides a variety of time correlated, simultaneous measurements from analog to source-code-referenced traces.

Agilent 1651B Logic Analyzer
32 channels of 100MHz transitional timing and 25MHz analysis on all channels, HP-IB and RS-232 compatible. Glitch detection on all channels, enhanced state compare, state X-Y chart mode, and state wave form display. Unit is configurable from front panel into two separate analyzers. Disk drive stores setups and measurement results for quick and easy recall, hard copy output to graphics printers. Flexible, passive probes. Intuitive, easy-to-use interface. Supports most 8-bit microprocessors.

Agilent 1660A Logic Analyzer
136 channels (including six Clock lines). 250MHz timing on all channels, 125MHz transition timing, 100MHz state speed, 4K memory depth on all channels.

Agilent 1662A Logic Analyzer
68 channels (including four clock lines). 250MHz timing on all channels, 125MHz transition timing, 100 MHz state speed, 4 K memory depth on all channels.

Agilent 1663A Logic Analyzer
34 channels (including two clock lines). 250MHz timing on all channels, 125MHz transition timing, 100MHz state speed, 4K memory depth on all channels.

HP 1670E Logic Analyzer
136 channel Analyzer with 250MHz timing, 100MHz state and 1MB memory depth.

Agilent 3245A Universal Source
Frequency range: 0 to 1MHz. AC amplitude: (p-p) .15625V to 20V. Includes sine, square, triangle and ARB wave forms. DC volts output: .078125V to 10V. DC current output: 0.1mA to 100mA.

Agilent 33120A Function/Arbitrary Wave Form Generator
100µHz - 15MHz: sine, square, triangle, ramp, noise, sine (X)/X, exponential rise and fall, cardiac and DC volts; Built in 16K deep arbitrary wave form generator, internal AM, FM, FSK and burst modulation; built in linear and log.

Agilent 3324A Synthesized/Function Generator
Sine wave, 1MHz - 21MHz; square, 1MHz - 11MHz; triangle, 1MHz - 11kHz; ramp, 1MHz - 11kHz; pulse, 1MHz - 11kHz.

Agilent 3325B Synthesized/Function Generator
Synth/function generator 1µHz - 21MHz; triangle, ramp and pulse 1µHz - 11MHz; square, 1µHz - 11kHz, negative and positive ramps; rear panel sync output for TTL compatibility; DC to 60MHz signal with 1µHz resolution. HP-IB.

Agilent 3400B RMS Voltmeter
Range: 10Hz to 10MHz. 1mV to 300V over 12 ranges.

Agilent 34401A Digital Multimeter
6.5 digits. DC range; 100mV to 1000V, Trms AC range: 100mV to 750V. Frequency range: 3Hz to 300kHz. Resistance range: 100O to 100MO. DC current: 10mA to 3A. AC current: 1A to 3A from 3Hz to 5kHz.

HP 34420A Nanovolt/Micro-Ohmmeter
Programmable voltage input; difference/ratio functions. Noise: 1.3nVrms, 8nVp-p, 1mV to 100V ranges. 7.5 digit resolution.   More Micro-Ohmmeters ...

Agilent 3457A Digital Multimeter
6.5 digits. DC range: 30mV to 300V. Trms AC range: 30mV to 300V. Frequency: 20Hz to 1MHz. Resistance range: 30O to 3GO. DC current: 300µA to 1A.

Agilent 3458A Digital Multimeter
8.5 digits. IEEE 488.1, IEEE-728. HP multimeter language. DC range: 100mV to 1000V. Resistance: 10O to 1GO. DC Current: 100nA to 1A. AC Voltage. AC current. Dig. & math functions.   More Digital Multimeters ...

Agilent 346A Noise Source
Frequency range: 10MHz - 18GHz. Very small change in reflection coefficient (<0.0l) from on to off to minimize the gain changes. The ENR is large enough (>5.2dB) to accurately measure noise figures of low noise gassFETS and UHF AMP. APC3.5 male connector.

Agilent 346B Noise Source
Solid state noise source. Frequency range: 10MHz - 18GHz. RF or microwave measurements. Low SWR: 1.25 from 5 - 18GHz. Calibration chart of ENR at 20 frequencies included. Calibration point every GHz. APC3.5 male connector standard.

Agilent 346C Broadband Noise Source
Freq. range: 10MHz - 26.5GHz. Excess noise ratio limits: 12 - 16dB from 10MHz - 12GHz, 14 - 17dB from 12.0 - 26.5GHz. Max. SWR (reflection coefficient) on and off: 10MHz - 18GHz - 1.25 (0.11), 18.0 - 26.5GHz - 1.35 (0.15). Power req.: 28V ±1V DC. Used with 8970A automatic noise figure meter.

Agilent 3560A Portable Signal Analyzer
Freq. range: 0.0625Hz to 40kHz. Freq. accuracy: 8Hz. Resolution bandwidth: 625µHz to 1440Hz. Avg. noise level: 100dBV dual channel. Dynamic range: 60dB to 10kHz.

Agilent 35660A Dual Channel Dynamic Signal Analyzer - FFT
102.4kHz single chan, 51.2kHz dual chan.. Spectrum analysis: 488µHz-102.4kHz. Network analysis: 244µHz-51.2kHz. Dynamic Range: 4-70dB. HP-IB.

Agilent 3561A Dynamic Signal Analyzer
Spectrum and network analysis, wave form recording, 1/3 and 1/1 octave analysis. Amplitude accuracy: ±15dB.80dB dynamic range. High speed (7.5Hz real time rate). Band selection zoom analysis for 640µHz resolution. Opt. 001: Extended non-volatile memory

Agilent 3562A FFT Dynamic Signal Analyzer
Dual channel FFT network, spectrum and wave form analyzer, freq. range: DC-100kHz: 150dB meas. Range; 80dB dynamic range; HP-IB.

Agilent 3566A Signal Analyzer
Freq. range 0.000122Hz to 128kHz. Freq. accuracy: 0.1Hz. Resolution bandwidth: 122µHz to 512Hz. Avg. noise level: -137dBV. Dynamic range: 72dB Multi-channel.

Agilent 35665A Signal Analyzer
Frequency range: 0.000244Hz to 102.4kHz. Frequency accuracy: 3Hz. Resolution bandwidth: 644µHz to 920Hz. Avg. noise level: -110dBV. Dual channel. Dynamic range: 72dB (FFT mode).

Agilent 35670A Dynamic Signal Analyzer
Dynamic signal analyzer FFT based spectrum/network analyzer. Provides spectrum, network, time domain and amplitude domain measurements. Frequency range: 0.000122Hz to 102.4kHz. The standard unit has 2 channels.

Agilent 3569A Real Time Frequency Analyzer
Frequency: 1/3 octave bands, single channel: 1.6Hz-20kHz (real time); octave bands, single channel: 2.0Hz-16kHz (real time); maximum octave bands, dual channel: 10kHz (1/3) and 8kHz (1/1). Dynamic range: 72dBfs.

Agilent 3577B Network Analyzer
Bandwidth: 5Hz to 200MHz. Range: 100dB. Accuracy: 0.02dB. Sensitivity: 130dBm.

Agilent 3585B Spectrum Analyzer
Automatic, self calibration, push button-operated, microprocessor controlled, 20Hz to 40.1MHz spectrum analyzer. 80 to 100dB dynamic range, 3Hz resolution bandwidth.

Agilent 3588A Spectrum Analyzer
Frequency range: 10Hz to 150MHz. Offers high performance spectrum measurements and simple scalar network measurements with its fully synthesized generator. 80 to 112 dB dynamic range.

Agilent 3589A Spectrum Network Analyzer
Frequency range: 10Hz to 150MHz, 1M ohm input specified from, 10Hz-40MHz. Amplitude: input range settings (characteristics only) 50O input (in 10dB steps) +20dBm to -20dBm 75 ohm input (in 10dB steps) +21.76dBm to -18.24dBm.

Agilent 3764A Digital Transmission Analyzer
Error and jitter measurements at 140MB/s or error measurements at 704kB/s, 2,8,34 and 140MB/s. Internal synthesizer for measurements from 1kB/s to 170MB/s at binary interfaces.

Agilent 3784A Digital Transmission Analyzer
G.821 error analysis at 704kb/s, 2,8 and 34MB/s. Optional jitter generation and measurement at 2,8 and 34MB/s. Clock synthesizer for rates between 1kb/s and 50MB/s. Optional V.11 interfaces for testing X.21 leased circuits.

Agilent 37900D Signaling Test Set
Multilink tester for SS No. 7 network signaling text decoding of level 2,3 and 4 messages. Automatic tracing of SS No. 7, ISDN, and mobile messaging sequences.

Agilent 4191A RF Impedance Analyzer
Measures 14 parameters with a maximum resolution of 4.5 digits. Internal synthesizer provides variable freq. from 1MHz to 1000MHz. Internal DC bias supply with auto sweep function covers the voltage range of ±40V. Max resolution: 100Hz with an accuracy of 3 PPM.

Agilent 4192A RF Impedance Analyzer
5Hz to 13MHz variable measuring frequency. Measure 11 impedance parameters including resistance, inductance, capacitance and gain phase relationships.

Agilent 4193A Vector Impedance Meter
Measures impedance magnitude and phase. An internal oscillator provides test signals from 400kHz to 110MHz. The test signal is constant current between 10MW and 100MW, depending on impedance range.

Agilent 4194A Impedance/Gain Phase Analyzer
Impedance Measurements; (Test freq.) 100Hz - 40MHz;1ZI, R, X: 10mO to 100MO; lyl, G, B: 10ns to 100s, 0 - + 180°; L: 1nh to 100kh; c: 10 fF to IF; D: .001 to 10; Q: .1 to 1000.

Agilent 4195A Network/Spectrum/Impedance Analyzer
Frequency range: 20Hz to 500MHz. Freq. resolution; 0.001Hz. color graphics, graphics analysis and direct copy capability.

Agilent 4263A LCR Meter
Test freq.: 100Hz, 120Hz, 1 kHz, 10kHz, 100kHz. Test levels: 50m, 1 00m, 250m, 500m, 1 V rms. Measurement range R: 1mO to 100MO; C: 1pF to 1F; L: 10nH to 100kH. 0.1% basic accuracy.
For a handheld LCR Meter, see the TES-2802 Datalogging LCR Meter

Agilent 4278A Capacitance Meter
Frequency range: 1 kHz and 1 MHz, + .02%; measurement parameters: C - D. Q. ESR. G; Signal level: .1 to 1 v rms, + 10%; c measurement range: (1kHz) .001pF to 200,000,µF, (1MHz high accuracy: .00001pF to 2663.00pF.

Agilent 4279A 1MHz C-V Meter
Frequency: 1MHz; measurement parameters: C-D, Q, ESR, G; test signal level: 20mV, 50mV, 100mV, 200mV, 500mV, and 1 v rms; C range: .00001pF to 1280pF.

Agilent 4284A Precision LCR Meter
Test freq.: 20Hz to 1MHz. 0.05% basic accuracy. Six digit resolution. Test signal level: 5mV to 2V rms. Measurement range R: .01MO to 99.9999MO; C: .01fF to 9.9999F, L: .01nH to 99.9999kH.
For a handheld LCR Meter, see the TES-2802 Datalogging LCR Meter

Agilent 4285A Precision LCR Meter
Test freq.: 75kHz to 30MHz - 0.1% basic accuracy. Test signal level: 5mV to 2V rms. Measurement range R: .01MO to 99.9999MO; C: .01fF to 999.999,µF, L: .001nH to 99.9999H.
For a handheld LCR Meter, see the TES-2802 Datalogging LCR Meter

Agilent 4286A RF LCR Meter
Frequency range: 1MHz - 1GHz; accuracy: 1.0%; measurement time: 15ms; measurement parameters: IZI, IYI, R, X, G, B, C, L, R, D, Q.
For a handheld LCR Meter, see the TES-2802 Datalogging LCR Meter

Agilent 4291A RF Impedance/Material Analyzer
Impedance parameters: Z, Y, R, X, G, B, CP, CS, LP, LS, RP, RS, D, Q; operative freq. 1MHz to 1.8GHz; freq. resolution: 1MHz; osc. level: .2mV to 1 V rms (1MHz to 1GHz).

Agilent 432A Power Meter
Frequency range: 10MHZ to 18GHz, 10µW to 10mW. Requires thermistor mount.

Agilent 432B Power Meter
Four ranges with full-scale readings of land 10µW and 1 and l0mW. Frequency determined by thermistor mount used.

Agilent 435B Power Meter
Frequency range: 100kHz to 26.5GHz. Power range: -65dBm to +44dBm (300pW to 25W) depending on sensor used. Compatible with all 8480 series power sensors.

Agilent 436A Power Meter
Frequency range: 100kHz to 18GHz, 10W to 100mW. 4-digit LED display. Requires thermistor mount. Option 022: Digital input/output, fully compatible with HP-IB.

Agilent 437B Power Meter
High performance, single channel, programmable, power meter compatible with Agilent 8480 family of thermocouples. Power range: -70dBm to +44dBm at frequencies from 100kHz to 50GHz depending on power sensor. Compatible with 848X series power sensors.

Agilent 438A Dual Power Meter
Dual input. Frequency range: 100kHz to 26.5GHz. Power range: -70dBm to +44dBm. (100pW to 25W). Ranges dependent on power sensor used. Option 002: Rear panel sensor connectors (in parallel with front panel) and additional reference oscillator with rear panel output.

Agilent 4396A Network/Spectrum Analyzer
Freq. range: (Network) 100kHz - 1.8GHz: (Spectrum) 2Hz - 1.8GHz; Resolution: (Network) 1MHz; (Spectrum) 1Hz - 3MHz; Power range: (Network) -60 to +20dBm; Spectrum amplitude range: to +30dBm.

Agilent 4934A Transmission Impairment Set
Frequency rate up to 110kHz. Noise to noise ground., noise with tone, and signal to noise ratio. 3 level impulse noise.

Agilent 4957A Protocol Analyzer
64Kb/s performance for quickly isolating problems during the installation, maintenance, and design of data communication networks and equip. Built in RS-232C, RS449, and V.35 interfaces. 768kb extended capture buffer. LCN and called/calling address filter efficiently locates problems in X.25 networks.

Agilent 53131A High Performance Universal Counter
Frequency range: 225MHz (3GHz); frequency resolution: 10 digits; sensitivity: 20 - 40mV; time interval resolution (single shot LSD) 500ps; HP-IB standard.

Agilent 53132A Universal Counter
225MHz, 12 digits, 150ps time interval resolution. 20 - 40mv sensitivity, HP-IB standard, full math, statistics, limit testing, auto pulse characterization.

Agilent 5314A Universal Counter
Freq. range: 10Hz to 100MHz. 7 digit LED display. Functions: freq., period, time interval, ratio & totalize, 10Hz to 10MHz direct; 1MHz to 100MHz prescaled. Opt. 001: High stability time base (TCXO). Opt. 002: Battery.

Agilent 5315A Universal Counter
Freq. range: DC - 100MHz. Functions: period, time interval, time interval average, time interval delay, ratio, totalize. Opt. 001: TCXO time base. Opt. 003: C-channel (1.0GHz). Opt. 120: 108-126 VAC.

Agilent 5316B Universal Counter
Input range: 0 - 100MHz (DC) or 30Hz (AC). Sensitivity: 10mV rms to 10MHz. 25mV rms to 100 MHz. Impedance: 1MO. HP-IB programmable (Standard).

Agilent 53181A RF Frequency Counter
Frequency range: 225MHz (1.5GHz, 3GHz) frequency resolution: 10 digits; sensitivity: 20 -40V; HP-IB standard.

Agilent 5334B Universal Counter
Frequency range: 0 - 100MHz (optional to 1300MHz). Frequency resolution: 9 digits. Sensitivity: 15mV. Time interval resolution: 2ns - 200ps. HP-IB standard.

Agilent 5335A Universal Counter
Frequency measurements to 200MHz. Functions: period; totalize, time interval, statistics, math. HP-IB. Time base: less than 3x10-7/month. Opt. 010: High stability time base: less than 5x10-10/day. Opt. 020: DC DVM; 100µV to 1000V. Opt. 030: 1.3GHz Channel. Opt. 040: Expanded HP-IB control.

Agilent 5342A Auto Frequency Counter
Frequency range: 10Hz to 18GHz. 11-digit LED display. Sensitivity - 25dBm. Wide FM tolerance. Opt. 001: High stability time base. Opt. 002: Amplitude measurement. Opt. 004: Digital-to-analog converter Opt. 011: Digital input/output (HP-IB)

Agilent 5343A Microwave Frequency Counter
Frequency Range: 500MHz to 26.5GHz. 11 digit LED display. 6MHz PP FM tolerance. Sensitivity -23Bm to 26.5GHz. Opt. 001: High stability time base Opt. 011: Digital input/output.

Agilent 5347A Microwave Counter/Power Meter
Frequency counter and power meter in one. Frequency range: 10Hz-20GHz. Sensitivity for 10Hz: 525MHz: 25mV rms; for 500MHz - 12.5GHz: -32dBm; for 12.4-20.0GHz: -27dBm. Uses 848X series power sensors.

Agilent 5348A Microwave Counter/Power Meter
Frequency range: 10Hz to 26.5GHz. Frequency resolution: 1Hz. Sensitivity: -32dBm. Max. input: +7dBm. Damage level: +25dBm peak. Power range: -70dBm to +20dBm.

Agilent 5350A Microwave Frequency Counter
Frequency: 10Hz to 20GHz. Sensitivity: 500MHz to 12.4GHz: -25dBm. Max. input: +7dBm. Accuracy: ±1 count ± time base X frequency. Resolution: selectable 1Hz to 1MHz. Max. deviation: 20MHz p-p Max. FM rate: 10MHz FM rate tolerance.

Agilent 5350B Microwave Counter
Frequency range: 10Hz to 20.0GHz. Frequency resolution: 1Hz. Sensitivity: -40dBm. Max. input: +7dBm. Damage level: +25dBm. HP-IB standard.

Agilent 5351B Microwave Counter
Frequency range: 10Hz to 26.5GHz. Frequency resolution: 1Hz. Sensitivity: -40dBm. Max. input: +7dBm. Damage level: +25dBm. HP-IB standard.

Agilent 5352B Microwave Counter
Frequency range: 10Hz to 40.0GHz. Frequency resolution: 1Hz. Sensitivity: -40dBm. Max. input: +7dBm. Damage level: +25dBm. HP-IB standard. Opt. 005: Frequency range: 500MHz to 46.0GHz.

Agilent 5355A Automatic Frequency Converter
Frequency range: 0.4 - 1.5GHz (condensed); Sensitivity: -15dBm; Max. input: +5dBm; Impedance: 50O nominal; damage level: +24dBm peak (fuse in bnc connector); pulse width: 16=50ns to 1s; pulse repetition rate: 100Hz to 2MHz.

Agilent 5356A Frequency Converter
Frequency converter used with 5345A. Frequency range 1.5 - 18GHz; sense -20dBm to 12.4GHz; sense -15dBm to 18GHz; Max. input +5dBm; pw min 100ns; pulse rep 50Hz min, 2MHz max.

Agilent 5356B Frequency Converter
Frequency range: 26.5GHz; when used with Agilent 5345A/5355A mainframe, you can make pulse - frequency measurements from 1.5GHz to 26.5GHz.

Agilent 5356C Frequency Counter
Frequency range: 40GHz; when used with Agilent 5345A/5355A mainframe, you can make pulse frequency measurements from 1.5GHz to 40GHz.

Agilent 5361B Pulsed/CW Microwave Counter
Frequency range: 10Hz to 20.0GHz. Frequency resolution: 1Hz. Sensitivity: -32dBm. Pulse width: 60ns minimum. HP-IB standard. Opt. 026: Frequency range: 500MHz to 26.5GHz. Opt. 040: Frequency range: 500MHz to 40.0 GHz.

Agilent 5370B Universal Time Interval 9-Digit Counter
Frequency range: 0.1Hz-100MHz. Period: 10ns-10s. +20PS SINGLE SHOT RESOLUTION. Sensitivity: 35mV rms sine wave times alternator. Trigger level: adjustable +2V with 10mV resolution.

Agilent 5371A Frequency and Time Interval Analyzer
Frequency range: DC - 500MHz. Measures dynamic and transient signal conditions. 150ps rms single shot resolution. Cont. frequency and time measurements. Histogram, time VAR displays. Pulse Width: 1ns min. Sensitivity: 15mV. Trigger resolution: 2mV. Totalizes to 500MHz.

Agilent 5372A Frequency and time Interval Analyzer
Frequency range: DC-18GHz continuous frequency profiling. Built in statistical and graphical analysis. Fast time interval histogram analysis. Pre-trigger display and time interval detect. 150ps rms single shot resolution, 2ps resolution with averaging.

Agilent 5373A Modulation Domain Pulse Analyzer
Frequency range: 8kHz to 500MHz. Frequency resolution: 10 digits. Time interval resolution: 150ps/1ps. Option 030: 2GHz Channel C.

Agilent 5384A Frequency Counter - 9 Digits
Frequency range: 10Hz-100MHz (Channel A), 50Hz-225MHz (Channel B). Sensitivity: 10-25mV rms sine wave. Period: 10ns - 0.1s Features: HP-IB control, 10MHz time base.

Agilent 5385A Frequency Counter - 9 Digits
Frequency range: 10Hz-100Hz (Channel A), 90Hz-1000MHz (Channel B). Sensitivity: 10-25mV rms sine wave. Period: 10ns-0.1s. Features: HP-IB control, 10MHz time base.

Agilent 5386A RF Frequency Counter
Frequency range: 10Hz to 3.0GHz. Frequency resolution: 9 digits. Sensitivity: -33dBm. Dynamic range: -23dBm to +dBm. Period A range: 10ns to 0.1s. HP-IB

Agilent 54121T Digitizing Oscilloscope
4 channels. Bandwidth: 20GHz. Time interval accuracy: 10ps repetitive. Memory/channel: 501 samples. Vertical resolution: 12 bits, 14 bits with averaging. Wave Form storage: 2 pixel, 4 wave forms. Input voltage range: 1 to 80mV/div.

Agilent 54122T Digitizing Oscilloscope
Same as 54121T, except bandwidth is 12.4GHz. Input voltage range: 1 mV to 2.4V/div.

Agilent 54123T Digitizing Oscilloscope
4 channels. Bandwidth: 34GHz. Time interval accuracy: 10ps repetitive. Memory/channel: 501 samples. Vertical resolution: 12 bits, 14 bits with averaging. Wave Form storage: 2 pixel, 4 wave forms. Input voltage range: 1 to 80mV/div.

Agilent 54124T Digitizing Oscilloscope
4 channels. Bandwidth: 50GHz. Time interval accuracy: 10ps repetitive. Memory/channel: 501 samples. Vertical resolution: 12 bits, 14 bits with averaging. Wave Form storage: 2 pixel, 4 wave forms. Input voltage range: 1 to 80mV/div.

Agilent 71400C Lightwave Signal Analyzer
Wavelength range: 750 to 870, 1200 to 1600nm. Modulation band-width: 100kHz to 22GHz. Sensitivity (optical): -62/-66dBm.

Agilent 71401C Lightwave Signal Analyzer
Wavelength range: 750 to 870, 1200 to 1600nm. Modulation band-width: 100kHz to 2.9GHz. Sensitivity (optical): -62/-66dBm.

Agilent 71450B Optical Spectrum Analyzer
Wavelength measurement range: 600nm to 1700nm; Input Sensitivity: -90dBm; Dynamic Range: 60dB. Used for testing LEDs, Fabry-Perot Lasers, or Distributed Feedback Lasers.

Agilent 71451B Optical Spectrum Analyzer
Wavelength measurement range: 600nm to 1700nm; Input Sensitivity: -90dBm; Dynamic Range: 60dB. Can characterize optical to optical devices such as couplers, filters, isolators, switches, and wavelength division multiplexers.

Agilent 71452B Optical Spectrum Analyzer
Wavelength measurement range: 600nm to 1700nm; Input sensitivity: -90dBm; Dynamic Range: 60dB. Used for testing optical amplifiers such as EDFA's and PDFAs (Erbium and Praseodymium Doped Fiber Amplifiers).

Agilent 8110A Pulse Generator
Mainframe frequency range: 1 Hz - 150MHz; Period: 6.65ns to 999ms; VFO and PLL timing, 10ps resolution; 2nS variable transitions; amplitude: 20V into 50O.

Agilent 8112A Pulse Generator
Frequency 50MHz. Period: 20ns to 950ms. Delay: 75ns to 950ms. Width: 10ns to 950ms. Transition time (fixed): 5ns typical. Amplitude: 32V p-p into open circuit. HP-IB. Fully programmable.

Agilent 8114A High Power Pulse Generator
Frequency range: 1Hz - 15MHz; period: 66.7ns - 999ms; Width: l0ns - 150ms; Amplitude: 2V p-p to 100V p-p (high impedance into 50O); 1V p-p - 50V p-p (50O into 50O) doubles into open circuit; Current: 40mA - 2A.

Agilent 8116A Pulse/Function Generator
Provides sine, triangle, square, haver functions and DC. Frequency range: 1MHz - 50MHz. 32V p-p for all wave forms. Variable (10ns min.) pulse width, 6ns transitions. Wide range of operating capability. Self-prompting operating concept. Error recognition and self test. Option 001: Burst and logarithmic sweep.

Agilent 8130A Pulse Generator
Repetition rate: up to 300MHz. Period: 3.33ns to 99.9ms. Width: 1.5ns to 99.9ms. Resolution: 3 digits, (best case: 10ps). Delay (fixed): 18ns. Variable range: 0ns to 99.9ms. Transition time: 1ns to 100ms. Output level: -4.90V to +5.00V. HP-IB capabilities. All modes and parameters are fully programmable.

Agilent 8131A Pulse Generator
Repetition rate: up to 500MHz. Period: 2ns to 99.9ms. Resolution: 3 digits, (best case: 10ps). Delay (fixed): 20ns. Variable range: 0ns to 99.9ms. Transition times: less than 200ps. Output levels: -4.90V to +5.00V. HP-IB capabilities. All modes and parameters are fully programmable.

Agilent 8133A Timing Generator
Frequency range: 33MHz - 3.0GHz; 100kHz resolution; Period: 300ps - 30ns, 1ps resolution; Width: 150ps - 10ns; Amplitude: .3 to 3V p-p.

Agilent 8347A General Purpose Amplifier
Frequency Range 100kHz to 3GHz, 25dB gain, 20dBm output power.

Agilent 8349B Microwave Amplifier
Frequency range 2 - 20GHz, 100mW output power, 15dB gain.

Agilent 8350B Sweep Oscillator Mainframe
Frequency and power levels determined by RF plug-in unit. Non-volatile memory to save sweeper programs. Accepts all 83500 series plug-ins. Accepts all 86200 series plug-ins with 11869A adapter.

Agilent 83522A RF Plug-In
For use with Agilent 8350A/B Sweeper. Freq. range 10MHz to 2.4GHz. Power output internally leveled to +0.25dB over entire range; power output >13dBm. Option 002: Programmable 70dB step attenuator.

Agilent 83525B Broadband RF Plug-In
Frequency range: 10MHz to 8.4GHz. Output power: + 2OmW/10mW. Option 002: Programmable 70dB Step Attenuator (10dB steps).

Agilent 83540A RF Plug-In
Frequency range: 2 to 8.4GHz. >40mW output. For use with Agilent 8350A/B sweeper. Option 002: 70dB Step Attenuator.

Agilent 83540B RF Plug-In
Frequency range: 2 to 8.4GHz. >20mW output. For use with Agilent 8350A/B Sweeper. Option 002: 70dB Step Attenuator

Agilent 83545A RF Plug-In
Frequency range: 5.9GHz to 12.4GHz. For use with Agilent 8350A/B Sweeper. Power leveled to ±.6dB. Power output level: 17dB. Option 002: 70dB Step Attenuator

Agilent 83554A Millimeter-Wave Source Module
Frequency range: 26.5 to 40.0GHz; maximum leveled power: +8dBm; Source output SWR: < 2.0.

Agilent 83555A Millimeter - Wave Source Module
Frequency range: 33.0 - 50.0GHz; Max. leveled power: +3dBm; wave guide output connector: EIA size WR22.

Agilent 83556A Millimeter - Wave Source Module
Frequency range: 40.0 - 60.0GHz; max. leveled power: +3dBm; wave guide output connector: EIA size WRl9.

Agilent 83570A RF Plug-In
Frequency range: 18 to 26.5GHz. Output: 10mW. For use with Agilent 8350A/B Sweeper.

Agilent 83572C Plug-In
Frequency range: 26.5GHz to 40GHz. Maximum leveled output: >10mW.

Agilent 83590A RF Plug-In
Frequency range: 2 - 20GHz. Broadband plug in. 10mW max. leveled power. For Agilent 8350 series mainframes. Option 002: 70dB step attenuator.

Agilent 83592A RF Plug-In
Frequency range: .01 to 20GHz. Calibrated output power with 0.ldB resolution. HP-IB. Internal leveling and slope standard, +l0dBm from 0.01 to 20GHz. Option 002: 70dB Step Attenuator.

Agilent 83592B RF Plug In
Frequency range: 10MHz-20GHz. 5 bands: .01 - 2.4GHz, 2.4 - 7GHz, 7 - 13.5GHz, 13.5 - 20GHz, .01 - 20GHz. 20mW out put power to 18.6GHz;. Ext. AM: 15dB, int.: 30dB. Ext. FM pulse in TTL. Used with 8350.

Agilent 83592C RF Plug-In
Frequency range: 0.01 -20GHz. -55dBc harmonics. HP-IB. Internal leveling and slope standard. Leveled output: 4mW/2.5mW. Option 002: 55dB Step Attenuator.

Agilent 83594A Sweeper Plug-In
Frequency range: 2 - 26.5GHz; Maximum leveled power: 4 - 10dBm. Power variation: ±0.7 to ±0.9dB.

Agilent 83595A RF Plug-In
Frequency range: 0.01-26.5GHz with 0.ldB resolution HP-IB. Internal leveling and slope standard. Leveled output: 2.5mW. Option 002: 55dB Step Attenuator.

Agilent 83595C RF Plug-In
Frequency range: .01 to 26.5GHz. 20mW maximum leveled output power to 20GHz, 10mW to 26.5GHz.

Agilent 83620A Synthesized Sweep Generator
Frequency range: .01 to 20GHz. Output power +10dBm. Harmonics: -50dBc.

Agilent 83622A Synthesized Sweep Generator
Frequency range: 2 to 20GHz. Output power +10dBm. Harmonics: 50dBc.

Agilent 83623A Synthesized Sweep Generator
Frequency range: .01 to 20GHz. Output power +17dBm. Harmonics: -25dBc.

Agilent 83624A Synthesized Sweep Generator
Frequency range: 2 to 20GHz. Output power +20dBm. Harmonics: -25dBc.

Agilent 83630A Synthesized Sweep Generator
Frequency range: 10MHz - 26.5GHz; Resolution 1 kHz std.; Maximum leveled Power: +10dBm, 50O output impedance.

Agilent 83640A Synthesized Sweep Generator
Frequency range: .01 to 40GHz. Output power +2dBm. Harmonics: 40dBc.

Agilent 83642A Synthesized Sweep Generator
Frequency range: 2 to 40GHz. Output power +2dBm. Harmonics: 40dBc.

Agilent 83650A Synthesized Sweeper
Frequency range: 10MHz to 50GHz. Maximum leveled power: +2.5dBm; Output connector: 2.4mm. Resolution: 1kHz.

Agilent 83711A Synthesized Generator
A synthesized CW generator that covers the range of 1 - 20GHz, 1kHz resolution harmonics; -50dBc; spurious (.3kHz) -60dBc; Meets or exceeds EN55011/CISPR 11/1190, Class "A" and mill-std 461C pt. 2 RE02/CE03/CS02/RS03.

Agilent 83712A Synthesized CW Generator
10MHz to 20GHz frequency range; 1kHz frequency resolution: 0.01dB res. Recommended for use with the Agilent 8970B noise figure meter.

Agilent 83731A Synthesized Signal Generator
Frequency range: 1.0 - 20.0GHz; Output range: +10 to -90dBm; Frequency resolution: 1kHz: Modulation: pulse. AM/FM.

Agilent 83732A Synthesized Signal Generator
Frequency range: .01 - 20.0GHz; Output range: +10 to -90dBm; Frequency resolution: 1kHz; Modulation: pulse. AM/FM.

Agilent 83751A Swept Frequency Synthesizer
Frequency range: 2 - 20GHz; Output power: l0dBm; Resolution: 1kHz; Modulation: pulse. AM/FM.

Agilent 83751B Swept Frequency Synthesizer
Frequency range: 2 - 20GHz; Output power: 17dBm; Resolution: 1kHz; Modulation: pulse. AM/FM.

Agilent 83752A Swept Frequency Synthesizer
Frequency range: .01 - 20GHz; Output power: 10dBm; Resolution: 1kHz; Modulation: pulse. AM/FM.

Agilent 83752B Swept Frequency Synthesizer
Frequency range: .01 - 20GHz; Output power: 17dBm; Resolution: 1kHz; Modulation: pulse. AM/FM.

Agilent 83810B Lightwave Signal Analyzer
Wavelength range: 1200 to 1600nm; modulation bandwidth: 9kHz to 22GHz; sensitivity (optical): - 4dBm.

Agilent 8447D Preamplifier
Better than 26dB gain, 100kHz to 1.3GHz, more than +7dBm output, ±1.5dB flat into 50O, BNC connectors.

Agilent 8447F Preamplifier
100kHz to 1.3GHz, 12.5dBm power output, equal or greater then 22dB gain, two channels.

Agilent 8449A Preamplifier
2GHz - 22GHz, 5dBm power output, 28dB gain.

Agilent 8449B Preamplifier
1GHz - 26.5GHz, 7dBm power output, 26dB gain.

Agilent 84812A Peak Power Sensor
Frequency range: 500MHz - 18GHz; Power range: -40 to +20dBm swr 720dB type-N connector.

Agilent 84815A Peak Power Sensor
Peak power sensor designed for use with the 8990A and 8991 Peak Power Analyzers. Frequency range: 50MHz to 18GHz. Power range: -32 to +20dBm. Type N connector.

Agilent 8504A Lightwave Precision Reflectometer
Wavelengths: 1300, 1500nm. Return loss range: 0 to 70dB. Measurement span: 1mm to 40cm (air). Two event distance resolution: 50nm (air).

Agilent 85044A 50 ohm Transmission/Reflection Test Set
Freq. Range 300kHz-3GHz, max. operating level is +20dBm, RF atten. range 0-70dB (10dB steps), DC bias connectors 50O BNC (F), test port connector precision 7mm. Requires use with Agilent 11851B Cable Kit.

Agilent 85044B Transmission/Reflection Test Set
Simultaneously measures impedance & transmission of 50 to 75O devises. 300kHz - 2GHz. Type N (F) test port.

Agilent 8508A Vector Voltmeter
Frequency range: 100 kHz to 2GHz; maximum input: 2V peak AC (+16dBm) + 50VDC; A(REF) channel minimum: 10 mV (-47dBm) 100kHz to 300kHz, 1mV (-47dBm) 300kHz to 3MHz 300µV. 3MHz to 1HGz (-57dBm) 3MHz to 2GHz. B channel noise level: 10µV (-8dBm).

Agilent 8509A Lightwave Polarization Analyzer
Wavelength range: 1200 to 1600nm.

Agilent 8510C Network Analyzer
Frequency: 45MHz to 50GHz; measurement results can be displayed on a large color CRT on one of two independent, yet identical channels. 80dB to 100dB dynamic range. Opt. 010: Time domain analysis.

Agilent 8511A Frequency Converter
Frequency: 26.5GHz. With the 8511A, the 8510B/C becomes a general purpose four channel magnitude/phase receiver. 3.5mm connectors.

Agilent 8511B Frequency Converter
Frequency: 50GHz. With the 8511B, the 8510B/C becomes a general purpose four channel magnitude/phase receiver. 2.4mm connectors.

Agilent 8560E - Spectrum Analyzer
Frequency range: 30Hz - 2.9GHz; resolution bandwidth range: (13dB): 1Hz to 1MHz; amplitude range: to +30dB.

Agilent 8561E Portable Spectrum Analyzer
Frequency range: 30Hz to 6.5GHz. Phase noise of <-80dBc/Hz at 100Hz offset from the carrier,<-97dBc/Hz at 1kHz offset, <-113dBc/Hz at 10kHz offset, and <-116dBc/Hz a 100kHz offset.

Agilent 8564E Spectrum Analyzer
Frequency range: 9kHz-40GHz; resolution bandwidth range: (-3dB): 1Hz to MHz; amplitude range to +30dBm.

Agilent 8565E Millimeter Spectrum Analyzer
Frequency range: 9kHz to 50GHz, front pane connectors 2.4 mm, HP-IB direct printer/plotter output, front panel cal. output bnc female 50 ohm.

Agilent 85640A Portable Tracking Generator
Provides the Agilent 8560 series spectrum analyzer with scalar measurement capability from 300kHz to 2.9GHz. Dynamic range greater than 100dB when combined with spectrum analyzer.

Agilent 85644A Tracking Source
Frequency range: 300kHz to 6.5GHz. Leveled output power up to +10dBm. Dynamic range up to 140dB.

Agilent 85645A Tracking Source
Frequency range: 300kHz to 26.5GHz. Leveled output power up to +10dBm. Dynamic range up to 140dB.

Agilent 85650A Quasi-Peak Adapter
Attach to spectrum analyzer to provide manual and automatic quasipeak detection recommended by CISPR Publication 16 and FCC Rules and Regulations. Vol. III Part 15J. Includes loudspeaker for audio signal and an adapter by-pass mode. Use with 8566B and 8568B Spectrum Analyzer.

Agilent 8566B Spectrum Analyzer
Frequency range: 100Hz to 22GHz: amplitude range: -134dBm to +30dBm, resolution: 10Hz to 3MHz. HP-IB interface. Useable to 300GHz with external mixers.

Agilent 8568B Spectrum Analyzer
Frequency range: 100Hz to 1500MHz. Provides powerful internal processing and stand-alone program execution. Can also store and plot more than eight full 1001-point traces or 80 compressed traces without an external computer.

Agilent 85685A RF Preselector for Agilent 8568B
Frequency range: 20Hz-2GHz. Multipurpose test receiver for Agilent 8566B, 8567A or 8568B.

Agilent 8590L Spectrum Analyzer
Frequency range: (50O) 9kHz-1.8GHz (75O) 1MHz - 1.8GHz (opt. 001); resolution: 4 digits, amplitude range: to +30dBm.

Agilent 8591C TV Analyzer
Frequency range: 9kHz to 1.8GHz. Frequency accuracy: 2kHz. Resolution bandwidth: 1kHz to 3MHz. Average noise level: -115dBm. Amplitude range: -115dBm to +30dBm.

Agilent 8591E Portable Spectrum Analyzer
Frequency range: 9kHz to 1.8GHz. Frequency accuracy: 2kHz. Resolution bandwidth: 1kHz to 3MHz. Average noise level: -115dBm. Amplitude range: -115dBm to +30dBm.

Agilent 8592L Portable Microwave Spectrum Analyzer
Frequency range: 9kHz to 22GHz; resolution: 4 digits; amplitude range: to +30dBm.

Agilent 8593E Portable Spectrum Analyzer
Frequency range: 9kHz to 22 GHz. Amplitude range - 127 to +30dBm. Internal memory for up to 50 traces to be stored. Time & date stamping. Built in memory card reader.

Agilent 8594E Portable RF Spectrum Analyzer
Frequency range 9kHz to 2.9GHz, amplitude - 127dBm to +30dBm, 30Hz to 3MHz resolution bandwidth range, 1dB relative frequency response, four digit resolution. Zoom window, peak table functions and card reader is standard.

Agilent 8595E Portable Spectrum Analyzer
Frequency range: 9kHz to 6.5GHz. Ampl. -127 to +30dBm. Internal memory for up to 50 traces to be stored. Time & date stamping. Built in memory card reader.

Agilent 8596E Spectrum Analyzer
Freq. range: 9kHz - 12.8GHz; resolution: 4 digits or 20Hz; amplitude range: to +30dBm.

Agilent 8642B Synthesized Signal Generator
Frequency range: 100kHz -2.115GHz. SSB phase noise at 20kHz offsets of 134dBc/Hz at 1GHz. +20dBm max. output level. AM, FM, IM and pulse modulation. Opt. 00 1: High stability time base.

Agilent 8643A Synthesized Signal Generator
Frequency range: 0.252 to 1030MHz. Resolution: 0.01Hz. Output level: +13 to -137dBm. Modulation: AM, FM and pulse. Remote programming interface: HP-IB (IEEE 488.2). SSB phase noise at 1GHz: -30dBc/Hz. Opt. 002: Frequency range: 0.252 - 2060MHz.

Agilent 8644B Synthesized Signal Generator
Frequency range: 0.252 to 1030MHz. Resolution: 0.01Hz. Output level: +16 to -137dBm. Modulation: AM, FM and pulse. Remote programming interface: HP-IB (IEEE 488.2). SSB phase noise at 1GHz: 136dBc/Hz. Option 002: Frequency range 0.252 - 2060MHz.

Agilent 8647A Synthesized Signal Generator
Frequency range: 250kHz to 1000MHz. Resolution 1Hz; Output range: +10 to -136dBm. 10 user definable sequences. Offers full HP-IB programmability and users SCPI programming codes.

Agilent 8648A Synthesized Signal Generator
Frequency range: 0.1 - 1000M Hz; Resolution: 1Hz; Output range: +10 to-136dBm; Modulation: FM, phase and AM; HP-IB.

Agilent 8648B Synthesized Signal Generator
Frequency range: 100kHz - 2000MHz; Resolution line: 1 Hz; Output range: +13 to -136dBm. Modulation: FM, AM and phase.

Agilent 8648C Synthesized Signal Generator
Frequency range 100kHz to 3.2GHz. Resolution 1Hz, output range +13 to -136dBm, and GPIB interface is standard.

Agilent 8656B Signal Generator
Frequency range: 100kHz to 990MHz. Resolution: 10Hz. Output level: +13dBm to -127dBm into 50O. AM and FM modulation. HP-IB programmable.

Agilent 8657A Signal Generator
Frequency range: 100kHz to 1040MHz. Resolution: 10Hz. Output level: +13dBm to -143.5dBm into 50O. AM and FM modulation. HP-IB programmable.

Agilent 8657B Signal Generator
Frequency range: 100kHz to 2060MHz image size. Camera will mount on a variety of scopes, spectrum analyzers and display monitors. HP-IB programmable.

Agilent 8657D Signal Generator
Frequency range: 100kHz - 1030MHz analog; Resolution: 1Hz.; Output range: +13 to -143.5dBm into 50 ohms; Modulation: FM/AM and pulse.

Agilent 8662A Synthesized Signal Generator
Frequency range: 10kHz to 1280MHz. 147dBc/Hz SSB phase noise at 10kHz offset and 0.1Hz frequency resolution. Fully HP-IB programmable.

Agilent 8663A Synthesized Signal Generator
Frequency range: 100kHz to 2560MHz. Output level: +16dBm to 129.9dBm. Digital sweep. AM-FM modulation. Fully HP-IB programmable. Opt. 002: Wide band linear phase modulation.

Agilent 8664A Synthesized Signal Generator
Frequency range: 0.1 to 3000MHz. Resolution: 0.01Hz. Output level: +13 to -139.9dBm. Modulation: AM,FM. Remote programming interface: HP-IB (IEEE-488.2). SSB phase noise at 1GHz: -117dBc/Hz. Opt. 004: SSB phase noise at 1GHz: -134dBc/Hz. Opt. 008: Pulse modulation.

Agilent 8665A Synthesized Signal Generator
Frequency range: 0.1 to 4200MHz. Resolution: 0.01Hz. Output level: +13 to -139.9dBm. Modulation: AM, FM. Remote programming interface: HP-IB (IEEE-488.2). SSB phase noise at 1GHz: -117dBc/Hz. Opt. 004: SSB phase noise at 1GHz: - 4dBc/Hz. Opt. 008: Pulse modulation.

Agilent 8665B Synthesized Signal Generator
Frequency range: 0.1 to 6000MHz. Resolution: 0.01 Hz. Output level: + 1 3 to -1 39.9dBm. Modulation: AM, FM. Remote programming interface: HP-IB (IEEE-488.2). SSB phase noise at 1GHz: -17dBc/Hz. Opt. 004: SSB phase noise at 1GHz: -134dBc/Hz. Opt. 008: Pulse modulation.

Agilent 8702B Lightwave Component Analyzer
300kHz to 20GHz. 850, 1300, or 1550nm operation. Reflection measurements with <1 mm resolution up to 50dB optical dynamic range. Requires RF interface kit, lightwave source, lightwave receiver, and fiber cable.

Agilent 8703A Lightwave Component Analyzer
Standard configuration includes an internal 1300nm fabry-perot (FP) laser and one 1300/1550nm receiver. Optional 1300 or 1550nm DFB internal laser sources are also available. Opt. 001: Ext. lightwave source input. Used with the Agilent 83424A or 83425A lightwave CW sources for additional 1550 or 1300nm DFB wavelength flexibility.

Agilent 8711B - Scalar Network Analyzer
Frequency Range: 300kHz - 300MHz; output power range: 0 - +16dBm; resolution: 1Hz; 100dB of system dynamic range: internal 3.5 in. disk drive (LIF/DOS).

Agilent 8712B - Vector Network Analyzer
Frequency Range: 300kHz - 1300MHz output power range: 0 - +16dBm; resolution: 1Hz; 100dB of sys. dynamic range; internal 3.5 in. disk drive (LIF/DOS).

Agilent 8713B - Scalar Network Analyzer
Frequency Range: 300kHz - 3.0 GHz; output power range: 0 - +10dBm; resolution: 1Hz, 100dB of sys. dynamic range; internal 3.5 in. disk drive (LIF/DOS).

Agilent 8714B - Vector Network Analyzer
Frequency Range: 300kGz - 3.0GHz; output power range: 0 - +10dBm, resolution: 1Hz, 100dB of sys. dynamic range; internal 3.5 in. disk drive (LIF/DOS).

Agilent 8719C Microwave Network Analyzer
Frequency range: 50MHz to 13.5GHz; frequency resolution: 100kHz. Maximum power: +10dBm. Power flatness: ±2.0dB.

Agilent 8720C Microwave Network Analyzer
Frequency range: 50MHz to 20GHz. Freq. resolution: 100kHz maximum power: +10dBm; power flatness: ±2.0dB. Color version of 8720 series. Option 010 Time domain analysis.

Agilent 8722C Network Analyzer
Freq. range: 50MHz - 40GHz; Resolution: 100kHz; Power range: -5 to -60dBm.

Agilent 8751A Network Analyzer
Frequency range: 5Hz to 500MHz. Frequency resolution: 1MHz. Power range: -50 to +15dBm. Power resolution: 0.1dB. Color display.

Agilent 8751A Gain Phase Analyzer
Freq. range: 100kHz-300MHz; Output level range: -15 to +5dBm: Resolution: 0.2dB; Freq. resolution: 1MHz.

Agilent 8752B Network Analyzer
Frequency range: 300kHz to 1.3GHz. Frequency solution: 1Hz. Power output: -20 to +5dBm. Power resolution: 0.1dB. Impedance: 75O. 100 dB dynamic range. Opt 003: 3GHz frequency extension.

Agilent 8752C Network Analyzer
Freq. range: 300kHz - 1.3GHz; Resolution: 1Hz; Output range: -20 to +5dBm.

Agilent 8753C Network Analyzer
Frequency range: 300 kHz to 3GHz. Integrated 1Hz resolution synthesized source. 100dB dynamic range. Color version of 8753 series. Opt 006: 6GHz frequency extension. Opt. 010: Time domain analysis.

Agilent 8753D - Network Analyzer
Frequency range: 30kHz - 3GHz includes built-in 85046A 50O S-Parameter test set color display and disk drive. Standard 50O unit has two 7mm test ports. Expandable frequency range to 6GHz with opt 006.

Agilent 8757C Scalar Network Analyzer
Measures insertion loss or gain, return loss, SWR; freq. range: 10MHz - 40GHz with coax, 110GHz with wave guide; dynamic range: 76dB. Color display. Opt. 001 4th detector input.

Agilent 8757D Scalar Network Analyzer
Frequency range: 10MHz to 110GHz. 76dB dynamic range (+16 to - 60dBm). Display channels: 4. Detector inputs: 3. External disk save/recall. Color display.

Agilent 8757E Scalar Network Analyzer
Frequency range 10 MHz to 110GHz, 76dB dynamic range (+16 to - 60dBm). 2 display channels, 2 detector inputs and a monochrome display.

Agilent 8780A Vector Signal Generator
Frequency range: 10MHz to 3GHz; Resolution: 1 Hz; Output: level range + 10dBm to -100dBm under 2.5GHz, +4dBm to -100dBm above 2.5GHz.

Agilent 8782B Vector Signal Generator
Frequency range: 1 MHz - 250MHz; Resolution: 1 Hz. RF output level: +7 to -100dBm; Digital modulation: BPSK, QPSK, 8PSK, 16QAM, 64QAM, 256QAM, 9PRS, 25PRS, 49PRS, and 81 PRS.

Agilent 8900D R.F. Peak Digital Power Meter
Pulse Widths: 1µs (100ns compare) to CW, 100Hz (0Hz compare) to 100kHz. 0 to 20dBm. 10mW and 100mW F.S.

Agilent 8901A Modulation Analyzer
Frequency range: 150kHz to 1300MHz. Measures AM/FM to 1% accuracy. 50 ohm impedance. Fully automatic.

Agilent 8901B Modulation Analyzer
Fully automatic. Measures RF frequency from 150kHz to 1300MHz. Measures RF power from 1mW to 1W. Measures AM, FM, and pulse modulation. Opt. 001: Rear panel connectors. Opt. 002: 1x10-9/day internal reference.

Agilent 8902A Measuring Receiver
Frequency range: 150kHz to 1300MHz. Power range: -20dBm to +30dBm (10µW to 1W). Modulation measurements: AM, FM, pulse.

Agilent 8902S Measurements System
Extends the frequency range of the Agilent 8902A by adding the Agilent 11793A microwave converter and a local oscillator. Delivers accuracy and resolution to 26.5GHz from +30 to -100dBm.

Agilent 8903B Audio Analyzer
Frequency range: 20Hz to 100kHz. Output range: 0.6mV to 6V open circuit. Resolution: 0.3% or better. Standard audio filters: 30kHz low pass, 80kHz low pass.

Agilent 8903E Distortion Analyzer
Frequency range: 20Hz to 100kHz. Distortion: (80kHz BW) -80dB, (500kHz BW) -70dB. Residual noise: -85dB (80kHz BW) -70dB (500kHz BW).

Agilent 8904A Multifunction Synthesizer
Digitally creates multitude of complex signals from 6 simple wave forms. Frequency range: DC - 600kHz (sine wave), 0Hz-50kHz (square, triangle and ramp). HP-IB programmable. Option 01: Adds 2 internal channels. Option 02: Adds 2nd internal synthesizer and output Option 03: Adds fast hop and digital modulation capability.

Agilent 8920A Communications Test Set
Frequency range: 250kHz-1GHz. Audio generator: DC-25kHz, RF frequency measurement range: 460Hz-1GHz. AF frequency measurement range: 20Hz-400Hz. O-Scope Bandwidth (3dB) 2Hz-50kHz. Tests cellular phones, land mobile radios and communication systems.

Agilent 8920D Dual-Mode Cellular Mobile Test System
Allows testing of existing analog cellular phones and North American dual-mode cellular phones complying with EIA/TIAIS-54/55 specifications.

Agilent 8921A Cell Test Set
Frequency Range: 250kHz - 1GHz. Audio generator: DC - 25kHz. RF Frequency Measurement Range: 400kHz -1GHz. AF frequency measurement range: 20Hz - 400kHz. O-Scope Bandwidth (3dB): 2Hz 50kHz. Allows automated installation and maintenance of cell sites.

Agilent 89440A Vector Signal Analyzer
Freq. range: 2MHz-1800MHz; Freq. resolution: .001Hz; Amplitude: -30 to +25dBm; Accuracy: ±1.8dB typical).

Agilent 89441A Vector Signal Analyzer
Freq. range: 2MHz-2650MHz; Freq. resolution: .001Hz; Amplitude: -50to +25dBm; Accuracy: ±2.0dB (±.5dB typical).

Agilent 8970B Noise Figure Meter
Freq. range: 10 to 1600MHz. Noise figure measurement range: 0 to 30dB. Freq. resolution: 1MHz. Gain resolution: 0.01dB. Max operating input power: -l0dBm.

Agilent 8971C Noise Figure Test Set
Freq. range: 10MHz to 26.5GHz. Input SWR: 10MHz to 18GHz(2.25), 18 to 26.5GHz (2.7). image and odd harmonic rejection: 20dB.

Agilent 8981B Vector Modulation Analyzer
Mod. IF frequency range: 50 to 200MHz. Mod. IF level range: -5 to -20dBm. Coherent ref. Level range: +10 to -20dBm. RF bandwidth: 70MHz.

Agilent 8990A Peak Analyzer
Frequency range: 20MHz to 40GHz (sensor dependent). Performs 7 automatic timing measurements: rise time, fall time, pulse width, pri, prf, duty, cycle, and delay. Power measurement range: -32 to +20dBm. Max pulse repetition rate 100MHz externally.

Agilent 8991A Peak Power Meter
Frequency range: 20MHz to 40GHz, sensor dependent. Power measurement range: - 33 to +20dBm. Max pulse repetition rate: 100MHz externally triggered, 1 MHz internally triggered.

Request a Quotation
Back to list of Manufacturers


Instrumentation Sales & Rentals
"The Ultimate Source of Quality Test Equipment"


PO Box 10188, 27 Legend Court
Ancaster, ON L9K 1P3 Canada
600 Main Street, PO Box 888
Tonawanda, NY 14151 USA
Phone: (800) 268-4928 or (905) 667-3991
Fax: (877) 336-8108 or (905) 304-6541