Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.
Advantest
Q8344A Optical Spectrum Analyzer
Measurement
range (wave lengths): 0.35 to 1.75µm. Max resolution: approx.
0.05nm ( at 0.85µm). Accuracy: ±0.l nm. Measurement
range (level): -70 to +10dBm. Accuracy: ±2.0dB. Measurement
time: 1.5s or less.
Advantest
Q8347 Optical Spectrum Analyzer
Measurement
range (wave length): 350nm to 1750nm; Measurement range (level):
-65 to + 10dBm; Input sensitivity: -52 to + 10dBm; Accuracy: <2.0dB.
Advantest
Q8381A Optical Spectrum Analyzer
Measurement
range (wavelength): 0.35 to 1.75µm. Resolution: 0.1, 0.2,
0.5, 1.0, 2.0, 5.0nm. Accuracy: ±0.5nm. Measurement range
(level): -85 to + 10dBm. Dynamic range: 40dB or more. Measurement
time: 0.8s or less (200nm - Span or less), 1.5s or less (500nm -
Span or less).
Advantest
Q8383 Optical Spectrum Analyzer
Measurement
range (wavelength): 550nm to 1750nm; Measurement range (level):
-85 to + 10dBm; Input sensitivity: -55 to +10dBm; Accuracy: within
± .4dB.
Agilent
71400C Lightwave Signal Analyzer
Wavelength
range: 750 to 870, 1200 to 1600nm. Modulation band-width: 100kHz
to 22GHz. Sensitivity (optical): -62/-66dBm.
Agilent
71401C Lightwave Signal Analyzer
Wavelength
range: 750 to 870, 1200 to 1600nm. Modulation band-width: 100kHz
to 2.9GHz. Sensitivity (optical): -62/-66dBm.
Agilent
71450B Optical Spectrum Analyzer
Wavelength
measurement range: 600nm to 1700nm; Input Sensitivity: -90dBm; Dynamic
Range: 60dB. Used for testing LEDs, Fabry-Perot Lasers, or Distributed
Feedback Lasers.
Agilent
71451B Optical Spectrum Analyzer
Wavelength
measurement range: 600nm to 1700nm; Input Sensitivity: -90dBm; Dynamic
Range: 60dB. Can characterize optical to optical devices such as
couplers, filters, isolators, switches, and wavelength division
multiplexers.
Agilent
71452B Optical Spectrum Analyzer
Wavelength
measurement range: 600nm to 1700nm; Input sensitivity: -90dBm; Dynamic
Range: 60dB. Used for testing optical amplifiers such as EDFA's
and PDFAs (Erbium and Praseodymium Doped Fiber Amplifiers).
Agilent
8140A Hand-Held Optical Loss Test Set
Wavelength
range: 400 to1700nm. Power range: +10 to-70dBm. Accuracy (at ref.
cond.): ±5%. Accepts plug-in modules.
Agilent
81400A Optical Sensor
400
to 1100nm. For Agilent 8140A.
Agilent
81401A Optical Sensor
750
to 1700nm. For Agilent 8140A.
Agilent
81411A LED Module
850nm.
For Agilent 8140A.
Agilent
81412A LED Module
1300nm.
For Agilent 8140A.
Agilent
81413A LED Module
1550nm.
For Agilent 8140A.
Agilent
8153A Lightwave Multimeter
Mainframe
offers 2 slots for plug-in modules. Modules can be combined in any
configuration. Can be used as a half channel power meter, as a half
channel light source, as a loss test set, or even as a return-loss
test set.
Agilent
81530A Power Sensor Module
Wavelength
range: 450 to 1020nm. Power range: +3 to -110dBm., Display resolution:
(dB): 0.001. Display resolution (W): 0.01pW. Accuracy (at ref. cond.)
±2.5% (600 to 1020nm).
Agilent
81531A Power Sensor Module
Wavelength
range: 800 to 1700nm. Power range: +3 to -90dBm. Display resolution
(dB): 0.001. Display resolution (W): 1pW. Accuracy (at ref. cond.)
±2.5% (1 000 to 1650nm).
Agilent
81532A Power Sensor Module
Wave
length range: 800 to1700nm. Power range: +3 to-110dBm. Display resolution:
0.001dB. Display resolution (w): 0.01pw. Accuracy (at ref. cond.):
-2.5% (1000 to 1650nm).
Agilent
81533A/81520A Optical Head Interface Module
Wavelength
range: 450 to 1020nm. Power range: +10 to -100dBm. Display resolution:
0.001dB. Display resolution (W): 0.1pW.
Agilent
81533/81521B Optical Head Interface Module
Wavelength
range: 900 to 1700nm. Power range: +3 to -80dBm. Display resolution:
0.001dB. Display resolution (W): 10pW.
Agilent
81541 Multimode LED Source Module
Central
wavelength: 850µm ±30mm. 50µm multimode fiber
output. Spectral bandwidth: 90µm. Output power: -17dBm.
Agilent
81542 Multimode LED Source Module
Central
Wavelength: 1300µm ±40µm. 50µm multimode
fiber output. Spectral bandwidth: 90dB. Output power: -20dBm.
Agilent
81542 Multimode Opt. 001 LED Source Module
Central
wavelength: 1300µm ±40µm. 62.5µm fiber
output (instead of 50µm). Spectral bandwidth: 90µm.
Output power: -20dBm.
Agilent
81551 Multimode Laser Source Module
Central
wavelength: 850nm ± 10µm, multimode. Spectral band-width:
1.5nm. Output power: -2dBm.
Agilent
81552 SM Laser Source Module
Central
wavelength: 1310nm ±20µm, single-mode. Spectral band-width:
2.5nm. Output power: 0dBm.
Agilent
81553 SM Laser Source Module
Central
wavelength: 1550nm ±20µm, single-mode. Spectral band-width:
4nm. Output power: 0dBm.
Agilent
81554 SM Laser Source Module
Central
wavelength: 1310/1550nm ±20µm, single-mode. Spectral
bandwidth: =2.5/4µm. Output power: -1dBm.
Agilent
8167A Tuneable Laser Source
Wavelength
Range: 1280nm to 1330nm; Wavelength accuracy: less than ±0.lnm;
Wavelength resolution: .001nm, 170MHz at 1300nm; Maximum output
power: -4dBm.
Agilent
8168B Tuneable Laser Source
Wavelength
range: 1500nm to 1565nm; Wavelength accuracy: less than ±0.lnm:
Wavelength resolution: .001nm, 125MHz at 1550nm. Maximum output
power: -4dBm.
Agilent
8168C Tuneable Laser Source
Wavelength
Range: 1470nm to 1580nm; Wavelength Accuracy: less than ±0.lnm;
Wavelength resolution: .001nm, 125MHz at 1550nm. Maximum output
power: +4dBm.
Agilent
83400A/B Lightwave Source Module
Range:
300kHz to 3GHz. 1300nm, 9/125µm fiber. For Agilent 8702B.
Agilent
83401A Lightwave Source Module
Range:
300kHz to 3GHz. 1300nm, 50/125µm fiber. For Agilent 8702B.
Agilent
83402A/B Lightwave Source Module
Range:
300kHz to 6GHz. 1300nm, 9/125µm fiber. For Agilent 8702B.
Agilent
83403B Lightwave Source Module
Range:
300kHz to 3GHz. 1550nm, 9/125µm fiber. For Agilent 8702B.
Agilent
83404A/B Lightwave Source Module
Range:
300kHz to 3GHz. 850nm, 50/125µm fiber. For Agilent 8702B.
Agilent
83410C Lightwave Receiver Module
Range:
300kHz to 3GHz. 1300/1.550nm, 62.5/125µm fiber. For Agilent
8702B.
Agilent
83411C Lightwave Receiver Module
Range:
300kHz to 6GHz. 1300/1550nm, 9/125µm fiber. For Agilent 8702B.
Agilent
83411D Lightwave Receiver Module
Range:
300kHz to 6GHz. 1300/1550nm, 9/125µm fiber. For Agilent 8702B.
Agilent
83412B Lightwave Receiver Module
Range:
300kHz to 3GHz. 850nm, 62.5/125µm fiber. For Agilent 8702B.
Agilent
83420A Lightwave Test Set
Wavelengths:
1300 to 1550nm. Modulation bandwidth: 130MHz to 20GHz.
Agilent
83421A Lightwave Source
130MHz
to 20GHz.
Agilent
83422A Lightwave Modulator
130MHz
to 30GHz.
Agilent
83423A Lightwave Receiver
Agilent
83440B/C/D Lightwave Converter
Wavelength
range: 1200 to 1600nm. Bandwidth (optical): DC to 6/20/32GHz.
Agilent
83475B Lightwave Communications Analyzer
Automated
mask and-template measurements, integrated optical channel. Wavelength
range: 780 to 1600nm. Two channel, 500MHz. General purpose oscilloscope.
Built in optical power meter.
Agilent
83484A/B Electrical Modules
The
83484A's two channels and the 83484B's single channel offer selectable
bandwidths of 26.5GHz or 50GHz.
Agilent
83485A/B Optical/Electrical Modules
Both
modules feature two measurement channels, one optical, one electrical.
Both channels have selectable bandwidth settings for selection between
lowest oscilloscope noise and highest bandwidth (20GHz with the
Agilent 82485A, 30GHz with the Agilent 83485B) for greater measurement
fidelity on high speed signals.
Agilent
83810B Lightwave Signal Analyzer
Wavelength
range: 1200 to 1600nm; modulation bandwidth: 9kHz to 22GHz; sensitivity
(optical): - 4dBm.
Agilent
8504A Lightwave Precision Reflectometer
Wavelengths:
1300, 1500nm. Return loss range: 0 to 70dB. Measurement span: 1mm
to 40cm (air). Two event distance resolution: 50nm (air).
Agilent
8509A Lightwave Polarization Analyzer
Wavelength
range: 1200 to 1600nm.
Agilent
8702B Lightwave Component Analyzer
300kHz
to 20GHz. 850, 1300, or 1550nm operation. Reflection measurements
with <1 mm resolution up to 50dB optical dynamic range. Requires
RF interface kit, lightwave source, lightwave receiver, and fiber
cable.
Agilent
8703A Lightwave Component Analyzer
Standard
configuration includes an internal 1300nm fabry-perot (FP) laser
and one 1300/1550nm receiver. Optional 1300 or 1550nm DFB internal
laser sources are also available. Opt. 001: Ext. lightwave source
input. Used with the Agilent 83424A or 83425A lightwave CW sources
for additional 1550 or 1300nm DFB wavelength flexibility.
Alcoa
Fujikura FSM15S Single Fusion Splicer
Splicing
is fully automatic by precision v-groove alignment. LCD monitor
with adjustable brightness and viewing angle provides 100x magnification
with perpendicular X and Y fiber images. Stores data for up to 100
splicers.
Alcoa
Fujikura 20RS12 Mass Fusion Splicer
Splices
1.25 micron fiber up to .900 micron fiber. Fuses 1, 2, 4, 6, 8,10,
12 fibers at once; ribbon and loose fiber tube.
Laser
Precision AM450 Optical Fiber Identifier
Determines
the presence, direction and intensity of light in optical fiber.
Applications: Dark fiber confirmation, determination of' signal
direction, fiber traffic identification, patch cord tracing.
Laser
Precision DB-2900A Optical Variable Attenuators
Low
reflection. Low insertion loss. High accuracy. Calibrated to 60dB.
Single mode 1310/1550nm. Bit error rate testing. Measuring optical
loss margins on fiber systems. Optical power meter/test set calibration.
Simulation of system loss. Optical component testing.
Laser
Precision LP-5000 Hand Held Fiber Optic Power Meter
Simple
3 button operation. Measurement range: -65dBm to +5dBm. Accuracy:
+0.3dB. Resolution: 0.1dB. FDDI testing. Cable acceptance testing.
Splicing. Connectorization. End-to-end testing of installed links.
Laser
Precision LP-5025 Fiber Optic Power Meter
Wavelengths:
850, 1310, 1550nm (26 calibrated wavelengths available). Measurement
range: +1dBm to -70dBm. Output power: -7dBm typical.
Laser
Precision LP-5100 Series Modulated LED Light Sources
Available
in 850nm, 1300nm or 850/1300nm dual wavelength models. Continuous
wave (CW) and modulated modes (270Hz, 2kHz).
Laser
Precision LP-5200 Series Modulated Laser Light Sources
Available
in 1310nm, 1550nm or 1310/1550nm dual wavelength models. Continuous
wave (CW) and modulated modes (270Hz, 2kHz).
Laser
Precision LTS-4410 Hand Held Loss Test Set
2
button control of instrument features. Independent 1310nm and 1545nm
laser sources (with LED indicators). 22 detector wavelengths. Modulation
detect LED indicates modulated signal in the range of 10 to 2500Hz
is detected. Readings in dB. Auto ranging.
Laser
Precision LTS-4510 Hand Held Loss Test Set
Same
as 4410 except 4 button control of all instrument features. Either
source may be CW or modulated at 30Hz or 2kHz. LEDs indicate the
source transmission mode.
Tektronix
P6701A Opto-Electronic Converter
Bandwidth:
DC to 700MHz. Analog analysis of optical signals in the wavelength
range 450 to 1050nm. Max. input optical power: 1mW. Opt. 02: Standard
SMA input connector.
Tektronix
TFC200 Optical Power Meter
Spectral
range: 750nm to 1700nm; Calibrated wavelengths: 780, 820, 850, 1060,
1300, 1310, 1550nm; Dynamic Range: +10dBm to -70dBm; Accuracy: ±3%.
Request
a Quotation
Back
to list of Categories
Instrumentation
Sales & Rentals
"The Ultimate Source of Quality Test Equipment"
|
PO Box 10188, 27 Legend Court
Ancaster, ON L9K 1P3 Canada
|
600
Main Street, PO Box 888
Tonawanda, NY 14151 USA
|
Phone: (800) 268-4928 or (905) 667-3991
Fax: (877) 336-8108 or (905) 304-6541