Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.

Fluke 2285B Data Logger
Maximum inputs & outputs: analog inputs: 100 channels per sys., Binary or BCD inputs: 100 channels per sys., Status outputs: 100 channels, Alarm outputs: 100 channels per sys., Analog outputs: 100 channels per sys. Built in thermocouple & RTD linearizations. Will handle equations involving addition, subtraction, multiplication, division and parentheses. Program memory: 20kB. 3.5 inch disk drive. Internal printer.

Fluke 2286A Data Acquisition System
Maximum inputs & outputs: analog inputs: 1500 channels per sys., Binary or BCD inputs: 1500 channels per sys., Status outputs: 1500 channels, Alarm outputs: 1500 channels per sys., Analog outputs: 1500 channels per sys. Built in thermocouple & RTD linearizations. Will handle equations involving addition, subtraction, multiplication, division and parentheses. Program memory: 32kB. 3.5 inch disk drive. Internal printer.

Fluke 2287A Helios Plus Mainframe
Mainframe capacity: 6 option slots; system capacity: -161A/D: 1000 channels; -165 A/D: 800 single-ended, 400 differential.

Fluke 2289A Helios-I Mainframe
Mainframe capacity: 6 option slots; system capacity 1500 channels.

Fluke 2620A Hydra Data Acquisition
21 analog input channels measures VDC, VAC, thermocouples, resistance, and frequency. Standard RS-232 interface, input AC or DC.

Fluke 2625A Hydra Series Data Logger
Configure via push button front panel or remotely via computer interface. Can operate as stand-alone, later connecting to a PC to upload data memory contents. Stored data also can be uploaded directly to PC via modem. Compatible with 9 different types of thermocouples. DC volts 300mV to 300V, RTDs 300W to 100MW, AC volts 20mV to 300V true rms, resistance 2 or 4 wire, and frequency input range 15Hz to 1MHz.

Fluke 2635A Hydra Series Data Logger
All the features of the 2620A plus increased data memory capability using removable memory card. Standard card is 256K. 1MB memory card is optional.

Fluke 2640A High Speed Data Acquisition System
Channel capacity: analog inputs 20, computed channels 10, digital I/0 & alarm outputs: 8 total, scan speed: slow 6 Ch/Sec nominal, medium 48 Ch/Sec nominal, fast 143 Ch/Sec nominal.

Fluke 2645A High Speed Data Acquisition System
Channel capacity: analog inputs 20; computed channels 10; digital I/0 & alarm outputs: 8 total; scan speed: slow 54 Ch/Sec nominal medium 200 Ch/Sec nominal, fast 10000 Ch/Sec nominal.