Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.
Fluke
2285B Data Logger
Maximum
inputs & outputs: analog inputs: 100 channels per sys., Binary
or BCD inputs: 100 channels per sys., Status outputs: 100 channels,
Alarm outputs: 100 channels per sys., Analog outputs: 100 channels
per sys. Built in thermocouple & RTD linearizations. Will handle
equations involving addition, subtraction, multiplication, division
and parentheses. Program memory: 20kB. 3.5 inch disk drive. Internal
printer.
Fluke
2286A Data Acquisition System
Maximum
inputs & outputs: analog inputs: 1500 channels per sys., Binary
or BCD inputs: 1500 channels per sys., Status outputs: 1500 channels,
Alarm outputs: 1500 channels per sys., Analog outputs: 1500 channels
per sys. Built in thermocouple & RTD linearizations. Will handle
equations involving addition, subtraction, multiplication, division
and parentheses. Program memory: 32kB. 3.5 inch disk drive. Internal
printer.
Fluke
2287A Helios Plus Mainframe
Mainframe
capacity: 6 option slots; system capacity: -161A/D: 1000 channels;
-165 A/D: 800 single-ended, 400 differential.
Fluke
2289A Helios-I Mainframe
Mainframe
capacity: 6 option slots; system capacity 1500 channels.
Fluke
2620A Hydra Data Acquisition
21
analog input channels measures VDC, VAC, thermocouples, resistance,
and frequency. Standard RS-232 interface, input AC or DC.
Fluke
2625A Hydra Series Data Logger
Configure
via push button front panel or remotely via computer interface.
Can operate as stand-alone, later connecting to a PC to upload data
memory contents. Stored data also can be uploaded directly to PC
via modem. Compatible with 9 different types of thermocouples. DC
volts 300mV to 300V, RTDs 300W to 100MW, AC volts 20mV to 300V true
rms, resistance 2 or 4 wire, and frequency input range 15Hz to 1MHz.
Fluke
2635A Hydra Series Data Logger
All
the features of the 2620A plus increased data memory capability
using removable memory card. Standard card is 256K. 1MB memory card
is optional.
Fluke
2640A High Speed Data Acquisition System
Channel
capacity: analog inputs 20, computed channels 10, digital I/0 &
alarm outputs: 8 total, scan speed: slow 6 Ch/Sec nominal, medium
48 Ch/Sec nominal, fast 143 Ch/Sec nominal.
Fluke
2645A High Speed Data Acquisition System
Channel
capacity: analog inputs 20; computed channels 10; digital I/0 &
alarm outputs: 8 total; scan speed: slow 54 Ch/Sec nominal medium
200 Ch/Sec nominal, fast 10000 Ch/Sec nominal.
Request
a Quotation
Back
to list of Categories
Instrumentation
Sales & Rentals
"The Ultimate Source of Quality Test Equipment"
|
PO Box 10188, 27 Legend Court
Ancaster, ON L9K 1P3 Canada
|
600
Main Street, PO Box 888
Tonawanda, NY 14151 USA
|
Phone: (800) 268-4928 or (905) 667-3991
Fax: (877) 336-8108 or (905) 304-6541