Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.

HP 346A Noise Source
Frequency range: 10MHz - 18GHz. Very small change in reflection coefficient (<0.0l) from on to off to minimize the gain changes. The ENR is large enough (>5.2dB) to accurately measure noise figures of low noise gassFETS and UHF AMP. APC3.5 male connector.

HP 346B Noise Source
Solid state noise source. Frequency range: 10MHz - 18GHz. RF or microwave measurements. Low SWR: 1.25 from 5 - 18GHz. Calibration chart of ENR at 20 frequencies included. Calibration point every GHz. APC3.5 male connector standard.

HP 346C Broadband Noise Source
Freq. range: 10MHz - 26.5GHz. Excess noise ratio limits: 12 - 16dB from 10MHz - 12GHz, 14 - 17dB from 12.0 - 26.5GHz. Max. SWR (reflection coefficient) on and off: 10MHz - 18GHz - 1.25 (0.11), 18.0 - 26.5GHz - 1.35 (0.15). Power req.: 28V ±1V DC. Used with 8970A automatic noise figure meter.

HP 432A Power Meter
Frequency range: 10MHZ to 18GHz, 10µW to 10mW. Requires thermistor mount.

HP 432B Power Meter
Four ranges with full-scale readings of land 10µW and 1 and l0mW. Frequency determined by thermistor mount used.

HP 435B Power Meter
Frequency range: 100kHz to 26.5GHz. Power range: -65dBm to +44dBm (300pW to 25W) depending on sensor used. Compatible with all 8480 series power sensors.

HP 436A Power Meter
Frequency range: 100kHz to 18GHz, 10W to 100mW. 4-digit LED display. Requires thermistor mount. Option 022: Digital input/output, fully compatible with HP-IB.

HP 437B Power Meter
High performance, single channel, programmable, power meter compatible with HP 8480 family of thermocouples. Power range: -70dBm to +44dBm at frequencies from 100kHz to 50GHz depending on power sensor. Compatible with 848X series power sensors.

HP 438A Dual Power Meter
Dual input. Frequency range: 100kHz to 26.5GHz. Power range: -70dBm to +44dBm. (100pW to 25W). Ranges dependent on power sensor used. Option 002: Rear panel sensor connectors (in parallel with front panel) and additional reference oscillator with rear panel output.

HP 84812A Peak Power Sensor
Frequency range: 500MHz - 18GHz; Power range: -40 to +20dBm swr 720dB type-N connector.

HP 84815A Peak Power Sensor
Peak power sensor designed for use with the 8990A and 8991 Peak Power Analyzers. Frequency range: 50MHz to 18GHz. Power range: -32 to +20dBm. Type N connector.

HP 8900D RF Peak Power Meter
Pulse Widths: 1µs (100ns compare) to CW, 100Hz (0Hz compare) to 100kHz. 0 to 20dBm. 10mW and 100mW F.S.

HP 8970B Noise Figure Meter
Freq. range: 10 to 1600MHz. Noise figure measurement range: 0 to 30dB. Freq. resolution: 1MHz. Gain resolution: 0.01dB. Max operating input power: -l0dBm.

HP 8971C Noise Figure Test Set
Freq. range: 10MHz to 26.5GHz. Input SWR: 10MHz to 18GHz(2.25), 18 to 26.5GHz (2.7). image and odd harmonic rejection: 20dB.

HP 8990A Peak Power Analyzer
Frequency range: 20MHz to 40GHz (sensor dependent). Performs 7 automatic timing measurements: rise time, fall time, pulse width, pri, prf, duty, cycle, and delay. Power measurement range: -32 to +20dBm. Max pulse repetition rate 100MHz externally.

HP 8991A Peak Power Analyzer
Frequency range: 20MHz to 40GHz, sensor dependent. Power measurement range: - 33 to +20dBm. Max pulse repetition rate: 100MHz externally triggered, 1 MHz internally triggered.