Some of the rental equipment on this page may also be available for sale. If you would like to purchase any of these rental assets, please check with us to find out if the instrument that you need is available for sale. If you need to purchase new equipment, please browse the New Equipment Catalogue.
Fluke
5100B Calibrator
Automatic
calibrator for: DC voltage, AC voltage, DC current, AC current.
Unit has all voltages, currents, frequencies and resistances needed
to calibrate analog and digital multimeters. Opt. 03: Wide band
AC voltage. Opt. 05: IEEE-488 interface. Opt. 06: EIA RS-232 interface. For Process Calibrators, see the Prova Process Calibrators
Fluke
5101B Calibrator
Automatic
calibrator with built-in mini-cassette deck for procedure storage.
Calibrates DC voltage, AC voltage, DC current, AC current. Unit
has all voltages, currents, frequencies and resistances needed to
calibrate analog and digital multimeters. Opt. 03: Wide band AC
voltage. Opt. 05: IEEE-488 interface. Opt. 06: EIA RS-232 interface. For Process Calibrators, see the Prova Process Calibrators
Fluke
5440B DC Calibrator
Voltage
output 0 to 1100V accuracy 0 -11V + or -2ppm +5mV. Current output
0 to 25mA. 11V to 22V 2ppm +8µV; 22 to 275V + 100µV;
275 to 1100V 3.5ppm + 400mV. For Process Calibrators, see the Prova Process Calibrators
Fluke
5500A Calibrator
DC
voltage range: 0 - 100V; DC current range: 0 - 11A; resistance range:
0 - 330MO; AC voltage range: 1.0mV - 1000V; AC current range: 0.033mA
- 11A; capacitance range: 0.33nf - 1.1mf. For Process Calibrators, see the Prova Process Calibrators
Fluke
5700A Calibrator
DC
voltage range: 22mV to 1100V. Resolution: 10nV to 100µV. Resistance:
0O to 100MO. AC voltage range: 2.2mV to 1100V. Resolution: 1nV to
1mV. Frequency: 10Hz to 1MHz. DC current: 220µA to 2.2A. Resolution:
1nA to 1µA. Frequency: 10Hz to 10kHz. For Process Calibrators, see the Prova Process Calibrators
Fluke
5790A AC Measurement Standard
Frequency
range: 10Hz - 1MHz; AC voltage range: 70µV - 1000V. Unit also
compatible with a 40 current shunts, and a wide band voltage option
extends frequency range to 30MHz. For Process Calibrators, see the Prova Process Calibrators
Request
a Quotation
Back
to list of Categories
Instrumentation
Sales & Rentals
"The Ultimate Source of Quality Test Equipment"
|
PO Box 10188, 27 Legend Court
Ancaster, ON L9K 1P3 Canada
|
600
Main Street, PO Box 888
Tonawanda, NY 14151 USA
|
Phone: (800) 268-4928 or (905) 667-3991
Fax: (877) 336-8108 or (905) 304-6541